RADIAL LEADED PTC | |
-- AN/AS MODEL -- |
Agency
Approvals: E175689 |
Features
|
Applications
|
Part
Numbering system ERF XX XXX XX X X |
Marking
system
|
Electrical characteristics (23 oC) |
Part Number |
Fig |
Hold |
Trip |
Rated |
Maxinum |
Pd |
Resistance Tolerance |
|
RMIN |
R1MAX |
|||||||
IH,A |
IT,A |
VMAX,V |
IMAX,A |
W |
||||
AN120 |
1 |
1.2 |
2.7 |
15 |
100 |
1.2 |
0.085 |
0.220 |
AS120 |
2 |
1.2 |
2.7 |
15 |
100 |
1.2 |
0.085 |
0.220 |
AN175 |
1 |
1.75 |
3.8 |
15 |
100 |
1.5 |
0.050 |
0.120 |
AS175 |
2 |
1.75 |
3.8 |
15 |
100 |
1.5 |
0.050 |
0.120 |
AN200 |
1 |
2.0 |
4.4 |
30 |
100 |
1.9 |
0.030 |
0.100 |
AN350 |
1 |
3.5 |
6.3 |
30 |
100 |
2.5 |
0.017 |
0.050 |
AN420 |
1 |
4.2 |
7.6 |
30 |
100 |
2.9 |
0.012 |
0.040 |
IH=Hold current-maximum current at which the
device will not trip at 23 still air. IT=Trip current-minimum current at which the device will always trip at 23 still air. VMAX=Maximum voltage device can withstand without damage at rated current. IMAX= Maximum fault current device can withstand without damage at rated voltage (V max). Pd=Typical power dissipated from device when in the tripped state in 23 still air environment. RMIN=Minimum device resistance at 23. R1MAX=Maximum device resistance at 23 1 hour after tripping. |
Typical time-to-trip-at 23 oC
|
Thermal
Derating Curve
|
AN/AS Product Dimensions (UNIT:mm) |
Part |
Fig |
A |
B |
C |
D |
F |
|||||
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
||
AN120 |
1 |
19.9 |
22.1 |
4.9 |
5.2 |
0.6 |
1.0 |
5.5 |
7.5 |
3.9 |
4.1 |
AS120 |
2 |
19.9 |
22.1 |
4.9 |
5.2 |
0.6 |
1.0 |
5.5 |
7.5 |
3.9 |
4.1 |
AN175 |
1 |
20.9 |
23.1 |
4.9 |
5.2 |
0.6 |
1.0 |
4.1 |
5.5 |
3.9 |
4.1 |
AS175 |
2 |
20.9 |
23.1 |
4.9 |
5.2 |
0.6 |
1.0 |
4.1 |
5.5 |
3.9 |
4.1 |
AN200 |
1 |
21.3 |
23.4 |
10.2 |
11.0 |
0.5 |
1.1 |
5.0 |
7.6 |
4.8 |
5.4 |
AN350 |
1 |
28.4 |
31.8 |
13.0 |
13.5 |
0.5 |
1.1 |
6.3 |
8.9 |
6.0 |
6.6 |
AN420 |
1 |
30.6 |
32.4 |
12.9 |
13.6 |
0.5 |
1.1 |
5.0 |
7.5 |
6.0 |
6.7 |
|